TX150 S5
Operating Manual
15
Introduction
Technical data
Mechanical values
Weight
Approx. 21-28 kg (depending on configuration)
Ventilation clearance
At least 200 mm on the front and on the rear side.
Environmental conditions
Condensation must be avoided during operation.
Noise level
Floorstand Model
Rack Model
Width
205 mm
482 mm (front panel)
Total depth
605 mm
642 mm (with handles)
Installation depth
-------
607 mm
Height
444 mm (with feet)
221 mm or 5 HU
Environment class 3K2
Environment class 2K2
EN 60721 Part 3-3
EN 60721 Part 3-2
Temperature:
–
Operating (3K2)
–
Transport (2K2)
10 °C ... 35 °C
-25 °C ... 60 °C
Humidity
10% ... 85%
Sound power level L
WAd
(ISO 9296)
≤
4.8 B (standby)
≤
5.2 B (operation)
Sound pressure level at bystander position
L
pAm
(ISO 9296)
≤
31 dB (A) (standby)
≤
34 dB (A) (operation)