Proceed as follows to get node information with Infrastructure Manager:
▶
Start up the GUI of the Infrastructure Manager and login.
▶
Display the node list from menu (
manage
>
node
).
▶
Select the target node and display the detail screen.
▶
Execute getting node information from action menu.
5.3.7
Enabling the boot watchdog
If the boot watchdog has been disabled for firmware upgrade purposes (see
"Disabling the boot watchdog" on page 72
), it has to be re-enabled to complete
the maintenance task.
Timer settings can be configured in the BIOS or using the iRMC S6 web
interface.
Enabling the boot watchdog in the BIOS
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Watchdog
set the
Action
setting to
Reset
.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Enabling the boot watchdog using the iRMC S6 web interface
▶
Log in to the iRMC S6 web interface.
▶
Select the
Settings
menu.
▶
Open the
Server Management
page.
▶
In the
Boot Watchdog
group, check the
Enable Boot Watchdog
option.
The
Enable Boot Watchdog
option must be selected.
▶
Select
Reset
from the
Watchdog Action
list.
▶
Click
Apply
for the changes to take effect.
Basic software procedures
86
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...