Resetting the boot retry counter in the BIOS
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
press the [+] or [-] keys to specify the maximum
number of boot attempts (0 to 7).
▶
Exit the BIOS.
Resetting the boot retry counter using iRMC S6 web interface
▶
Enter the iRMC S6 web interface.
▶
Select the
Server Management
menu.
▶
The following boot retry counter settings are available under
ASR&R
Options
:
▶
Under
Retry counter max
specify the maximum number of attempts to
boot the OS (0 to 7).
▶
Under
Retry counter
the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
▶
Click
Apply
for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
5.3.6
Resetting the error status after replacing memory
modules or CPU
5.3.6.1
Resetting the error status after replacing memory modules
In case of a memory error, an error counter may be set for the defective
memory module.
Basic software procedures
82
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...