More information on suitable backup software solutions and related
documentation is available from the Fujitsu web pages.
5.3.5
Resetting the boot retry counter
The boot retry counter is decremented from its preset value every time the
POST watchdog initiates a system reboot. When the value has reached ’0’, the
system will shut down and power off.
Viewing the boot retry counter
The current boot retry counter status is available in the BIOS:
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Retry Counter
the current number of remaining boot attempts
is displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
▶
Exit the BIOS.
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
Please note, if the customer does not know about the original boot retry
values:
If the system boots up and no further errors occur within 6 hours after
that successful boot attempt, the boot retry counter will automatically be
reset to its default value. Please take into account, that the specified
number of boot attempts can only be determined after this period of
time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Basic software procedures
TX1320 M5
Upgrade and Maintenance Manual
81
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...