Installing the new system board
▶
If applicable, install the TPM, see
"Installing the TPM" on page 303
.
▶
Check the settings on the new system board, see
.
▶
Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel, see
▶
Lower the system board carefully into the chassis.
▶
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in
show the
centering bolts).
▶
Fasten the system board with the eight screws, see
.
▶
Remove the plastic cover from the CPU socket of the new system board.
▶
Remove the CPU from the defective system board, see
.
▶
Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
▶
Install the CPU on the new system board, see
.
▶
Fit the protective plastic cover onto the socket of the defective system board
which will be sent back to spares.
Returned system boards without this cover probably have to be
scrapped.
▶
Install the heat sink, see
"Installing the standard heat sink" on page 239
"Installing the performance heat sink" on page 242
.
▶
If applicable, install the power distribution board, see
power distribution board" on page 128
.
▶
If applicable, install the HDD cage, see
"Installing the 2.5-inch HDD cage"
.
▶
If applicable, install all HDD modules, see
.
System board and components
TX1320 M5
Upgrade and Maintenance Manual
343
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...