6.4.4
Replacing the power distribution board
Field Replaceable Unit
(FRU)
Hardware: 25 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Suspending BitLocker functionality" on page 71
.
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
"Getting access to the component" on page 48
▶
If applicable, remove the ODD, see
"Removing the ODD" on page 252
.
▶
If applicable, remove the RDX drive, see
.
Removing the defective power distribution board
▶
"Removing a hot-plug PSU" on page 120
.
Power supply unit (PSU)
124
Upgrade and Maintenance Manual
TX1320 M5