68
Upgrade and Maintenance Manual
TX1320 M4
Basic software procedures
Ê
Ask the system administrator to suspend BitLocker-protection on the system
volume, using the
BitLocker Drive Encryption
control panel item.
I
This will temporarily disable BitLocker for maintenance purposes.
The volume will not be decrypted and no keys will be discarded.
Ê
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
Ê
Select the system volume, and click
Suspend Protection
.
Ê
Click
Yes
to confirm that your data will not be protected while BitLocker
is suspended.
I
In order to determine which features are accessible through the
BitLocker setup wizard, it may be necessary to modify the BitLocker
Group Policy settings.
For more information on how to suspend BitLocker drive encryption, see
the Microsoft TechNet library at
http://technet.microsoft.com/library/cc731549.aspx.
For more information, see the Fujitsu web pages.
5.1.2
Disabling the boot watchdog
The boot watchdog determines whether the operating system boots within a
preset time frame. If the watchdog timer expires, the system will automatically
reboot.
If the system is to be started from removable boot media for firmware upgrade
purposes, the boot watchdog needs to be disabled before starting maintenance
task. Otherwise, the boot watchdog might initiate a system reboot before the
flash process is complete.
V
CAUTION!
An incomplete firmware upgrade process may render the server
inaccessible or result in damaged/destroyed hardware.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Disabling the boot watchdog in the BIOS
Ê
Enter the BIOS.
Summary of Contents for PRIMERGY TX1320 M4
Page 20: ...Upgrade and Maintenance Manual TX1320 M4 Contents ...
Page 32: ...32 Upgrade and Maintenance Manual TX1320 M4 Before you start ...
Page 46: ...46 Upgrade and Maintenance Manual TX1320 M4 Important information ...
Page 96: ...96 Upgrade and Maintenance Manual TX1320 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual TX1320 M4 Power supply unit PSU ...
Page 216: ...216 Upgrade and Maintenance Manual TX1320 M4 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual TX1320 M4 Accessible drives ...
Page 312: ...312 Upgrade and Maintenance Manual TX1320 M4 System board and components ...
Page 340: ...340 Upgrade and Maintenance Manual TX1320 M4 Appendix A ...
Page 342: ...342 Upgrade and Maintenance Manual TX1320 M4 Appendix B ...
Page 367: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...