14.6.1.4 Software configuration
In order to install the ESXi to the Dual microSD 64GB Enterprise, the VMware
ESXi installer CD is required.To obtain the ESXi installer CD by purchasing the
OEM Media Kit, or downloading the ESXi Custom Image ISO file from
VMware's website and burn the image to the CD.
https://www.vmware.com/go/download-vsphere
.
To Install the ESXi to the Dual microSD 64GB Enterprise by following the steps
below:
Ê
Disconnect all storage devices from the server beside the Dual microSD
64GB Enterprise.
Ê
Power on the server. Once the server has been started, then enter the BIOS
setup menu and select the DVD drive as primary boot device.
Ê
Insert the CD into the DVD drive and reboot the server. The server will boot
from the installer CD.
Ê
Follow the on-screen instructions to install the ESXi. When the installation is
complete, you will be asked to reboot the server.
Ê
While the server is rebooting, enter the BIOS setup menu again and select
the Dual microSD 64GB Enterprise as primary boot device.
The installation of the ESXi to the Dual microSD 64GB Enterprise is complete.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
I
The Dual microSD 64GB Enterprise can be used only for boot device. Do
not use VMFS on the Dual microSD 64GB Enterprise because of not
meeting required endurance. For more information, see the VMware
Knowledge Base 2145210.
Summary of Contents for PRIMERGY TX1320 M4
Page 20: ...Upgrade and Maintenance Manual TX1320 M4 Contents ...
Page 32: ...32 Upgrade and Maintenance Manual TX1320 M4 Before you start ...
Page 46: ...46 Upgrade and Maintenance Manual TX1320 M4 Important information ...
Page 96: ...96 Upgrade and Maintenance Manual TX1320 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual TX1320 M4 Power supply unit PSU ...
Page 216: ...216 Upgrade and Maintenance Manual TX1320 M4 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual TX1320 M4 Accessible drives ...
Page 312: ...312 Upgrade and Maintenance Manual TX1320 M4 System board and components ...
Page 340: ...340 Upgrade and Maintenance Manual TX1320 M4 Appendix A ...
Page 342: ...342 Upgrade and Maintenance Manual TX1320 M4 Appendix B ...
Page 367: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...