TX1320 M4
Upgrade and Maintenance Manual
137
Hard disk drives (HDD) and solid state drives (SSD)
7.3.2.3
Concluding steps
Ê
Ê
"Connecting the power cord" on page 60
Ê
"Switching on the server" on page 63
I
To configure the installed HDD, see your controller manual.
7.3.3
Removing 3.5-inch non hot-plug HDDs
7.3.3.1
Preliminary steps
Ê
If the HDD to be removed is combined into a RAID array, proceed as follows:
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
tool-less
RAID level Procedure
RAID 0
V
CAUTION!
RAID 0 provides no data redundancy.
In case of an HDD/SSD module is defect, all data
are lost!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array will
not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process, see
section
"Performing a RAID array rebuild" on
.
Summary of Contents for PRIMERGY TX1320 M4
Page 20: ...Upgrade and Maintenance Manual TX1320 M4 Contents ...
Page 32: ...32 Upgrade and Maintenance Manual TX1320 M4 Before you start ...
Page 46: ...46 Upgrade and Maintenance Manual TX1320 M4 Important information ...
Page 96: ...96 Upgrade and Maintenance Manual TX1320 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual TX1320 M4 Power supply unit PSU ...
Page 216: ...216 Upgrade and Maintenance Manual TX1320 M4 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual TX1320 M4 Accessible drives ...
Page 312: ...312 Upgrade and Maintenance Manual TX1320 M4 System board and components ...
Page 340: ...340 Upgrade and Maintenance Manual TX1320 M4 Appendix A ...
Page 342: ...342 Upgrade and Maintenance Manual TX1320 M4 Appendix B ...
Page 367: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...