17.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM or expansion cards installed
1 CPU with heat sink
installed in slot CPU 1
1 memory module
installed in slot DIMM-1A
1 PSU
installed on chassis
Table 5: Minimum startup configuration - components
Cable
Notes
Power cable
Table 6: Minimum startup configuration - cables
▶
"Unlocking the server" on page 39
▶
"Removing the bay cover" on page 40
▶
"Shutting down the server" on page 41
▶
"Disconnecting the power cord" on page 42
▶
Take the system down to its minimum startup configuration.
▶
"Connecting the power cord" on page 56
.
▶
Connect a display to the server.
▶
"Switching on the server" on page 57
▶
"Installing the bay cover" on page 58
▶
"Locking the server" on page 59
Appendix A
236
Upgrade and Maintenance Manual
TX1310 M5
Summary of Contents for PRIMERGY TX1310 M5
Page 14: ...Content Upgrade and Maintenance Manual TX1310 M5 ...
Page 80: ...Power supply unit PSU 80 Upgrade and Maintenance Manual TX1310 M5 ...
Page 124: ...Expansion cards 124 Upgrade and Maintenance Manual TX1310 M5 ...
Page 156: ...Processor CPU 156 Upgrade and Maintenance Manual TX1310 M5 ...
Page 174: ...Front panel and front USB 174 Upgrade and Maintenance Manual TX1310 M5 ...
Page 216: ...System board and components 216 Upgrade and Maintenance Manual TX1310 M5 ...
Page 238: ...Appendix A 238 Upgrade and Maintenance Manual TX1310 M5 ...
Page 257: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT July 2021 ...