Installation
Connecting the storage subsystem
3.5.1
Connecting SCSI cables
Ê
Switch off the CPU.
Ê
Connect the SCSI connection cable on the CPU to the 68-pin SCSI input
connector on the storage subsystem (marked 1 in figure 2 on page 20).
The next storage subsystem can be connected using the 68-pin SCSI output
connector (marked 2 in figure 2 on page 20).
A maximum of two PRIMERGY S10 storage subsystems can be daisy-
chained on one SCSI bus.
3.5.2
Connecting the power cable
Ê
Connect the power cable of the storage subsystem to a free insulated socket
on the grounded connector strip in the rack (see the Technical Manual for the
rack).
You can set the voltage to the desired voltage range (115 V or 230 V) using
the voltage switch (marked 4 in figure 2 on page 20) on the back of the
system.
If the power is on, the green power LED on the back of the system lights up.