Hard disk and solid state drives
6.3.3
Unlocking the HDD/SSD module
Figure 38: Unlocking the 2.5-inch HDD/SSD module
Ê
Release the locking mechanism as follows:
1. Press the two green tabs of the locking lever together (1).
2. Push the handle of the HDD/SSD module fully in the direction of the
arrow (2). The HDD/SSD module is now unlocked.
6.3.4
Removing the HDD/SSD module
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait for at least 60 seconds.
I
This period is necessary for the RAID controller to recognize that an
HDD/SSD module has been removed and for the hard disk drive to
come to a stop.
Ê
Pull the HDD/SSD module out completely.