172
Maintenance Manual
RX900
S1
Expansion cards and BBU
Ê
Select the battery holder as follows:
–
A: Insert the BBU for the Modular RAID controller in PCIe slot #8.
–
B: Inset the BBU for one of the SAS RAID controllers.
Ê
Insert the battery at a slight angle behind the clips (1).
Ê
Carefully press the battery into the holder until it engages under the two
locking hooks (2).
Ê
Route the BBU cable through the cable clamps (3).
Ê
Install the BBU holder with the BBU in the chassis.