"Switching on the server" on page 60
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the
message
CPU has been changed
.
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the [F2] function key
to enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the
Exit
menu.
●
Select
Commit settings and Exit
.
●
Verify that the Global Error indicator stops flashing.
▶
"Installing the front cover with lock" on page 61
.
▶
"Resuming BitLocker functionality" on page 104
.
11.4
Replacing a CPU or heat sink
For CPU1 or CPU2 on the bottom system board:
Field Replaceable Unit
(FRU)
Hardware: 20 minutes
Software: 5 minutes
Tools:
– Phillips PH2 / (+) No. 2 screw driver (for cover 2)
– Torx 30 screw driver (for CPU heatsink)
For CPU 3 or CPU 4 on the top system board:
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Software: 5 minutes
Processor (CPU)
RX4770 M6
Upgrade and Maintenance Manual
269