Ambient conditions
Condensation during operation must be avoided!
Noise level (depending on the configuration)
The acoustic noise values are depending on the system configuration.
Electrical data of PSU: 1600 W Platinum
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5°C ... 40°C (with ATD 40° C)
10°C ... 35°C (without ATD, i.e. only for
CPUs XEON
®
Gold 6154 and XEON
®
Platinum 8168, 8180 & 8180M)
Transport (2K2)
-25°C ... 60°C
Humidity
10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296)
< 6.5 B (standby)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
(ISO 9296) (at < 23 °C)
< 47.4 db(A) (standby)
< 47.4 db(A) (operation)
Rated voltage range
100 V - 240 V
Frequency 50 Hz
-
60 Hz
Max. rated current
Each PSU:
12 A - 8 A
System max.: 20 A - 8 A
Effective power
2189 W
Apparent power
2213 VA
Heat dissipation
7880.4 KJ/h (7469.2 BTU/h)
Main power fuse
16 A
Protection class
I