RX4770 M2
Operating Manual
25
Functional overview
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level (depending on the configuration)
The acoustic noise values are depending on the system configuration.
Rack (W x D x H)
482.6 mm (Bezel) / 444.8 mm (Body) x 765.0 mm x
176.0 mm
Mounting Depth Rack
728 mm
Height Unit Rack
4 U
19" rackmount
Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Weight
minimum 32 kg; maximum 46 kg (actual weight may
vary depending on configuration)
Rack integration kit
rack integration kit as option
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5°C ... 40°C (with Cool-safe
®
ATD)
10°C ... 35°C (without Cool-safe
®
ATD)
Transport (2K2)
-25°C ... 60°C
Humidity
10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296)
< 6.5 B (standby)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
(ISO 9296) (at < 23 °C)
< 50 db(A) (standby)
< 50 db(A) (operation)
Summary of Contents for PRIMERGY RX4770 M2
Page 6: ...Operating Manual RX4770 M2 ...
Page 10: ...Operating Manual RX4770 M2 Contents ...
Page 14: ...14 Operating Manual RX4770 M2 Preface ...
Page 28: ...28 Operating Manual RX4770 M2 Functional overview ...
Page 42: ...42 Operating Manual RX4770 M2 Important information ...
Page 78: ...78 Operating Manual RX4770 M2 Property and data protection ...
Page 84: ...84 Operating Manual RX4770 M2 Troubleshooting and tips ...