RX300 S7
Operating Manual
89
Troubleshooting and tips
8.9
Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê
Remove and reinstall the drive while the system is switched ON.
If the drive continues to be shown as defective, then replace it.
8.10 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the ServerView Suite DVD 2.
8.11
Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê
Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
8.12 Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message
The above log is output or the above notification is issued by ServerView when
the ambient temperature is within 30 to 35°C, which is near the upper limit of the
temperature boundaries (10 to 35°C). This is to notify the administrator before
the ambient temperature actually exceeds the range of the temperature
boundaries.
Summary of Contents for PRIMERGY RX300 S7
Page 1: ...Operating Manual English PRIMERGY RX300 S7 Server Operating manual Edition June 2013 ...
Page 6: ...Operating Manual RX300 S7 ...
Page 10: ...Operating Manual RX300 S7 Contents ...
Page 34: ...34 Operating Manual RX300 S7 Functional overview ...
Page 62: ...62 Operating Manual RX300 S7 Hardware installation ...
Page 84: ...84 Operating Manual RX300 S7 Property and data protection ...