100
Operating manual
RX300
S5
Non-hot-plug components
CSS components
8.2
Non-hot-plug components
V
CAUTION!
The actions described in this section may only be performed by
personnel with the appropriate technical training. (The device can be
seriously damaged if it is opened without authorization or if repairs are
attempted by untrained personnel.)
Please observe the safety information in
chapter "Important information"
on page 27
.
If a defective non-hot-plug component is detected (further information can be
found in chapter
"Starting up and operation" on page 59
and the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY
ServerView Suite DVD 2), proceed as follows:
Ê
Exit all applications and shut down the server properly (see section
"Switching the server on and off" on page 71
).
Ê
Unplug all power plugs.
Ê
Open the server (see section
"Opening/closing the housing" on page 106
).
Ê
Press the Indicate CSS button on the system board (see the technical
manual for the system board D2619).
The PRIMERGY Diagnostic LED of the defective CSS component lights up
orange, thereby indicating which CSS component (memory module or
expansion card) on the system board must be replaced (see technical
manual for the system board D2619).