178
Upgrade and Maintenance Manual
TX2560 M2 / RX2560 M2
Hard disk drive (HDD) / solid state drive (SSD)
7.2.12 Replacing a 2.5-inch HDD/SSD module
I
PCIe SSDs SFF are mounted in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
V
CAUTION!
●
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
hot-plug HDD/SSD module" on page 558
●
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration with a RAID controller:
Only RAID level 1, 1E, 10, 5, 50, 6 or 60 is allowed.
RAID configuration without a RAID controller:
Please follow the instruction provided separately.
●
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.12.1 Preliminary steps
Ê
"Locating the defective server" on page 55
Ê
When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page 71
Ê
"Locating the defective component" on page 57
Only applicable for removing intact HDD/SSD modules:
Ê
Before removing a non-defective HDD/SSD module, put the drive into
"Offline" state using your RAID configuration software.
Customer Replaceable Unit
(CRU)
Hardware:
5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...