TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
139
Basic software procedures
Ê
From the
Fast!UTIL Options
menu, select
Configuration Settings
, and press
[Enter]
.
Ê
From the
Configuration Settings
menu, select
Adapter Settings
, and press
[Enter]
.
Ê
Note down the new 16-digit WWN address found under
Adapter Port Name
.
Ê
Press
[Esc]
to return to the main menu and exit the QLogic BIOS utility.
Ê
Inform the customer about the changed WWN address.
5.2.18 Using the Chassis ID Prom Tool
The Chassis ID EPROM located on a dedicated Chassis ID board or on your
server’s front panel board contains system information like server name and
model, housing type, serial number and manufacturing data.
In order to integrate your system into the ServerView management environment
and to enable server installation using the ServerView Installation Manager,
system data needs to be complete and correct.
After replacing the Chassis ID EPROM, system information has to be entered
using the Chassis ID Prom tool. The tool and further instructions are available
to maintenance personnel from the Fujitsu Technology Solutions Extranet:
https://partners.ts.fujitsu.com/com/service/ps/Servers/PRIMERGY/
Ê
Select your PRIMERGY system from the main area of the page.
Ê
From the categories selection, choose
Software & Tools Documentation
.
Ê
In the
Tools
area click
Tools: Chassis-IDProm Tool
to download the file
(
tool-chassis-Idprom-Tool.zip
).
I
For the Japanese market, follow the instructions provided separately.
Note on Advanced Thermal Design (ATD)
I
If the Advanced Thermal Design (ATD) option is available and has been
enabled for your server, please set information within the Chassis ID
Prom Tool accordingly.
The ATD option can only be ordered from the manufacturer as a factory
preset. To find out if your server is ATD-enabled, check for the ATD logo
on the identification rating plate.
For ATD logo and further information on Advanced Thermal Design
(ATD), please refer to your server’s operating manual.
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...