TX2560 M2 / RX2560 M2
Operating Manual
17
Functional overview
Accessible drives / components
With most configurations the TX2560 M2 / RX2560 M2 offers 3 x 1.6” bay in the
accessible drives area located at the top of the tower server (or at the right side
of the rack) for various ODD and or backup drives.
USB connectors
Two USB 3.0 connectors on the front of the device support activities carried out
by the service technician. The maximum length of the external cable is two
meters for the USB connectors on the front.
Another four USB connectors are available on the rear of the device
(2x USB 3.0 and 2x USB 2.0).
Power supply
In its basic configuration, the server has a hot-pluggable power supply unit that
adjusts automatically to any power voltage in the range from 100 V to 240 V
(Platinum) or 200 V to 240 V (Titanium). As an option, the power supply can be
expanded with an extra power supply unit to create a redundant power supply.
If a power supply unit fails, the redundant configuration assures continued
operation. The defective power supply unit can be replaced during operation
(for further details see the "FUJITSU Server PRIMERGY TX2560 M2 / RX2560
M2 Server Upgrade and Maintenance Manual").
Advanced Thermal Design
The Advanced Thermal Design option allows you to operate the system with a
wider temperature range either of 5 °C to 40 °C or 5 °C to 45 °C, depending on
your system and configuration.
V
CAUTION
In a system that is configured with Advanced Thermal Design, only
certain components which support the respectively increased higher
operating temperature range may be installed and used. For applicable
restrictions, please refer to the official configurator tool.
This option can only be ordered from the
manufacturer and is indicated by the respective
logo on the identification rating plate.
Summary of Contents for PRIMERGY RX2560 M2
Page 8: ...Operating Manual TX2560 M2 RX2560 M2 Contents ...
Page 12: ...12 Operating Manual TX2560 M2 RX2560 M2 Introduction ...
Page 32: ...32 Operating Manual TX2560 M2 RX2560 M2 Functional overview ...
Page 48: ...48 Operating Manual TX2560 M2 RX2560 M2 Important information ...
Page 80: ...80 Operating Manual TX2560 M2 RX2560 M2 Starting up and operation ...
Page 82: ...82 Operating Manual TX2560 M2 RX2560 M2 Property and data protection ...
Page 90: ...90 Operating Manual TX2560 M2 RX2560 M2 Troubleshooting and tips ...