5.2.3
Removing backup and optical disk media
▶
Ask the system administrator to eject all remaining backup or optical media
from the backup drive or ODD before removing it from the server.
▶
If the backup media cannot be ejected by conventional means, and it is
mandatory that the cartridge be removed prior to returning the drive for
repair or disposing it, a manual tape extraction needs to be performed.
Please contact Fujitsu support, if "forcible" tape ejection is necessary.
Fujitsu does not assume responsibility for any damage to the tape drive,
the data cartridge/tape or for the loss of any data resulting from manual
tape extraction procedures.
5.2.4
Verifying and configuring the backup software
solution
This task only applies to Japan.
Depending on the backup software solution, it may be necessary to disable or
delete the backup drive from the backup software drive list before starting the
maintenance task.
For more information on suitable backup software solutions and related
documentation, see the Fujitsu web pages.
5.2.5
Switching on the ID indicator
For easy identification of the server, switch on the ID indicator, especially when
working in a datacenter environment or a server room. The ID indicator can
also be activated via the iRMC S5 web interface and its status is reported to
the iRMC S5.
"Locating the defective server" on page 49
the "ServerView Suite Local Service Concept (LSC)", the iRMC user
guides or the Infrastructure Manager documentation.
Basic software procedures
90
Upgrade and Maintenance Manual
RX2540 M6
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...