Installing the dummy cover
Figure 47: Installing the dummy cover
▶
Insert the dummy cover into the empty bay with the impressed arrow symbol
facing to the left (see circle).
▶
Push the dummy cover into its bay until it locks in place.
CAUTION
▶
Always install dummy covers into unused bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Concluding steps
No steps needed.
6.3.3
Replacing a hot-plug PSU
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools:
Phillips PH1 / (+) No. 1 screw driver (for DC PSU -48 V)
The procedure of replacing an AC PSU or a DC PSU differs only in
disconnecting/connecting the power cord.
Power supply unit (PSU)
130
Upgrade and Maintenance Manual
RX2540 M6