330
Upgrade and Maintenance Manual
RX2540 M4
Main memory
10.1.1 Population rules
– Non-ECC DIMMs are not supported on this platform.
– x4 and x8 DIMMs cannot be mixed in the same channel.
– Mixing of LRDIMM with RDIMM type is not allowed per platform.
– Mixing of non-3DS and 3DS LRDIMMs is not allowed per platform.
– DIMMs with different frequencies can be mixed in the system.
– Lowest frequency determines the system memory speed.
– There should be at least one DDR4 DIMM per CPU socket (slot 1A/1G).
– If two DIMMs with different capacity are installed in one channel, the DIMM
with the higher capacity has to be placed in slot 1 of a channel, e.g. 1A, 1B.
– If DIMMs with different ranks are installed in one channel, the DIMM with the
higher rank has to be placed in slot 1 of a channel, e.g. 1A, 1B.
– If DIMMs with different ranks are installed on one CPU socket, follow
memory module population order.
Figure 222: Mixing of DIMM types within a channel
Memory module population order DDR4 only
– If two DIMMs with different capacity are installed in one channel, the one
with the higher capacity has to be placed in slot 1 of a channel, e.g. 1A, 1B.
DIMM types
RDIMM
3DS RDIMM
LRDIMM
3DS LRDIMM
RDIMM
allowed
not allowed
not allowed
not allowed
3DS RDIMMs
not allowed
allowed
not allowed
not allowed
LRDIMM
not allowed
not allowed
allowed
not allowed
3DS LRDIMM
not allowed
not allowed
not allowed
allowed
Summary of Contents for PRIMERGY RX2540 M4
Page 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Page 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Page 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Page 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Page 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Page 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Page 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Page 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Page 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Page 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Page 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...