5.3.17
Using the Chassis ID Prom Tool
The front panel (front panel module, front panel board or front panel on QRL)
contains the Chassis ID EPROM that stores the following system information:
–
server name and model
–
housing type
–
serial number
–
manufacturing data
–
information depending on the configuration:
– installed HDD/SSD backplanes
– installed extension boxes
– installed expansion cards (for example Retimer, EP5xxi)
In order to integrate your system into the ServerView Management
environment and to enable server installation using the ServerView Installation
Manager, system information needs to be completed and corrected.
System information has to be updated after one of the following tasks:
–
Front panel module
– replacing (with the same type)
– changing (from front panel module 2.5-inch to front panel on QRL)
–
HDD/SSD backplane (2.5-inch, 3.5-inch, PCIe)
– installing
– removing
– changing (the technology, for example from SAS/SATA to PCIe)
–
Extension boxes
– installing
– removing
–
Specified expansion cards (for example Retimer, EP5xxi)
– replacing
Basic software procedures
94
Upgrade and Maintenance Manual
RX2520 M5
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...