RX2520 M4
Upgrade and Maintenance Manual
93
Basic software procedures
Ê
Press
[Esc]
to return to the main menu and exit the QLogic BIOS utility.
Ê
Inform the customer about the changed WWN address.
5.2.17 Using the Chassis ID Prom Tool
The Chassis ID EPROM located on a dedicated Chassis ID board or on the front
panel board of your server contains system information like server name and
model, housing type, serial number and manufacturing data.
In order to integrate your system into the ServerView management environment
and to enable server installation using the ServerView Installation Manager,
system data needs to be complete and correct.
After replacing the Chassis ID EPROM, system information has to be entered
using the Chassis ID Prom tool. The tool and further instructions are available
to maintenance personnel from the Fujitsu web pages:
https://partners.ts.fujitsu.com/com/service/ps/Servers/PRIMERGY/
Ê
Select your PRIMERGY system from the main area of the page.
Ê
From the categories selection, choose
Software & Tools Documentation
.
Ê
In the
Tools
area click
Tools: Chassis-IDProm Tool
to download the file
(
tool-chassis-Idprom-Tool.zip
).
I
For Japan:
Follow the instructions provided separately.
Note on Advanced Thermal Design (ATD)
I
If the Advanced Thermal Design (ATD) option is available and has been
enabled for your server, please set information within the Chassis ID
Prom Tool accordingly.
The ATD option can only be ordered from the manufacturer as a factory
preset. To find out if your server is ATD-enabled, check for the ATD logo
on the identification rating plate.
For ATD logo and more information on Advanced Thermal Design (ATD),
see the operating manual of your server.
V
CAUTION!
Please note that you can only set the ATD flag. Resetting the ATD flag
using the Chassis ID Prom Tool is not possible!
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...