402
Upgrade and Maintenance Manual
RX2520
M4
Appendix A
16.2.3.2 Indicators on the I/O panel
ID, CSS, and Global Error indicators
Figure 283: Global Error, ID and CSS indicators
Pos. Indicator
Status
Description
1
ID
indicator,
see also
"iRMC-
related
status
signals" on
page 403
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
interface or the ID button on the front panel for
easy identification.
blue
flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
Global
Error
indicator,
see also
"iRMC-
related
status
signals" on
page 403
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified range
– Defective sensor
– CPU error
– Error detected by server management
software
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...