400
Upgrade and Maintenance Manual
RX2520
M4
Appendix A
16.2.2.3 Indicators on the hot-plug HDD/SSD module
Figure 281: Indicators on the hot-plug HDD/SSD module
Pos.
Label
Indicator
Status
Description
1
Access
indicator
off
The HDD/SSD is inactive.
green on
The HDD/SSD being accessed
2
Error
indicator
off
No HDD/SSD error detected.
orange on
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and needs
replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
orange
flashing
slowly
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has been
combined into a RAID array.
!