RX2520 M4
Upgrade and Maintenance Manual
259
Processor (CPU)
11.3.2 Removing the heat sink
Figure 157: Removing the heat sink
Ê
Loosen the captive screws (see circles) following the sequence described
below and using a #2 screw driver:
V
CAUTION!
Please do not use an electric screw driver.
1. Loosen the four captive screws one by one (in the sequence 4 to 1)
rotating them a half-turn each.
2. Loosen the captive screws 4 and then 3 rotating them two or three turns
each.
3. Repeat the step 2 until the screws 4 and 3 are completely loosened.
4. Loosen the captive screws 2 and then 1 rotating them two or three turns
each.
5. Repeat the step 4 until the screws 2 and 1 are completely loosened.
Ê
Lift the heat sink together with the CPU frame out of the chassis.
V
CAUTION!
Pay special attention not to damage any system board components
surrounding the CPU socket.
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...