256
Upgrade and Maintenance Manual
RX2520
M4
Processor (CPU)
Figure 156: Installing the heat sink
Ê
Carefully seat the heat sink onto the CPU socket.
I
Take care of the pins. There is only one position which fits.
Ê
Fasten the four captive screws in the sequence printed on the heat sink
(1 to 4) by hand, by proceeding as follows:
Torque: 1.4 Nm (not used in Japan)
Ê
At first, fasten the captive screws 1 and 2 completely.
Ê
Fasten the captive screws 3 and 4 completely.
11.2.4 Upgrading the main memory
Ê
Select an adequate memory configuration for "2 CPUs populated", see
section
"Basic information" on page 248
.
Ê
Install memory modules, see section
"Installing memory modules" on
.