Exchanging the heat sink
Processors
6.3
Exchanging the heat sink
Ê
Open the server as described in the
chapter “Preparation” on page 17
Ê
Remove the air duct.
Ê
Remove the four screws of the heat sink in diagonally opposite sequence
(see
Ê
Turn the heat sink carefully back and forth to loosen it. Then lift it out to
remove it.
Ê
Clean the surface of the processor with a lint-free cloth.
Ê
Fit the heat sink on the processor such that airflow arrow is facing to the rear
side of the server (see
Ê
Attach the heat sink with four screws. Tighten the screws in diagonally
opposite sequence (see
Ê
Reinstall the air duct. Ensure that the hooks on the air duct (see
) engage on the fan’s rear panel.
Ê
Close the server, plug in the power plugs, and switch on the server as
described in the
chapter “Completion” on page 41