16.3
Onboard settings
USB 2.0
USB 2.0
USB 3.2
Gen 2
Slot 3
JP3
PWR1
FRONT
PWR2
P30
PC98
Intel
C256
USB 3.2
Gen 2
FAN4
SYS
FAN5
SYS
FAN6
SYS
ODD
PWR
PANEL
TYPE C
FRONT
JP2 JP1
Clear RTC
Figure 283: Jumper
Jumper
Status
Description
JP1/JP2
Default (place to keep the jumper)
Password
Skip (JP1)
Password Skip enabled
This jumper setting will permanently
delete the current BIOS password and
apply default BIOS settings.
Recovery
BIOS (JP2)
Recovery BIOS enabled
JP3
BIOS WP
Default
BIOS Flash Write Protect enabled
16.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
Appendix A
360
Upgrade and Maintenance Manual
RX1330 M5
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...