
5.3.20
Performing a fan test
Notes on replacing a defective fan
After replacing a defective system fan or PSU containing a defective fan,
the fan error indicators will stay lit until the next fan test. By default, a fan
test is automatically started every 24 hours. The first automatic fan test
being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC S5 web interface
▶
Log into the iRMC S5 web interface.
The
System
menu is displayed on default.
▶
Open the
Cooling
page.
▶
Expand the
Cooling Devices
group.
▶
Click
Start Fan Test
.
For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
▶
Open the ServerView Operations Manager and log in.
▶
Under
Administration
select
Server Configuration
.
▶
In the hierarchy tree of the
Server list
tab, select the server to be
configured.
▶
In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking
GO...
. In the left-hand section of
the window, the
Configuration
tab is being activated.
▶
In the navigation area of the
Configuration
tab, select
Other Settings
.
▶
Under
Daily Fan Test
, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
Basic software procedures
96
Upgrade and Maintenance Manual
RX1330 M4
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...