Status
Description
flashing green slowly
The BMC firmware is starting up after the server has
been connected to the mains.
AC connected indicator (6)
Status
Description
green on
– The server is switched off and connected to the
mains (standby mode).
– The server has been switched on but Power Cycle
Delay settings delay it from turning on for a
specified time.
After connecting the server to the mains, it
will take about 60 seconds until the server
will enter standby mode and can be switched
on.
off
– The server is switched off and not connected to the
mains.
– The server is switched on and operating normally.
iRMC-related status signals
ID indicator
Global error
indicator
Description
flashing blue
off
A remote connection has been
established. Local VGA output has been
disabled during the remote session.
flashing blue
flashing orange An emergency flash of the iRMC firmware
is in progress.
For more information about the iRMC flash procedure, see "Basic
software procedures" in the "FUJITSU Server PRIMERGY RX1330 M4
Upgrade and Maintenance Manual".