![Fujitsu PRIMERGY RX1330 M3 Upgrade And Maintenance Manual Download Page 85](http://html.mh-extra.com/html/fujitsu/primergy-rx1330-m3/primergy-rx1330-m3_upgrade-and-maintenance-manual_121086085.webp)
RX1330 M3
Upgrade and Maintenance Manual
85
Basic software procedures
Ê
Under
Boot Retry Counter
the current number of remaining boot attempts is
displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
Ê
Exit the BIOS.
5.2.6.2
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
I
Please note, if the customer does not know about the original boot
retry values:
If the system boots up and no further errors occur within 6 hours after that
successful boot attempt, the boot retry counter will automatically be reset
to its default value. Please take into account, that the specified number
of boot attempts can only be determined after this period of time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Resetting the boot retry counter in the BIOS
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Retry Counter
press the
[+]
or
[-]
keys to specify the maximum
number of boot attempts (0 to 7).
Ê
Exit the BIOS.
Resetting the boot retry counter using the ServerView Operations Manager
Ê
In the ServerView Operations Manager
Administration
view, select
Server
Configuration
.
Ê
If more than one server is managed in SVOM, select the target server and
click
Next
.
Ê
From the
Server Configuration
menu pane, choose
Restart Options
.
Ê
Under
Reboot Retries
, specify the maximum number of boot attempts (0 to 7)
in the
Default for reboot tries
field.
Summary of Contents for PRIMERGY RX1330 M3
Page 20: ...Upgrade and Maintenance Manual RX1330 M3 Contents ...
Page 48: ...48 Upgrade and Maintenance Manual RX1330 M3 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual RX1330 M3 Basic hardware procedures ...
Page 132: ...132 Upgrade and Maintenance Manual RX1330 M3 Power supply unit PSU ...
Page 178: ...178 Upgrade and Maintenance Manual RX1330 M3 Hard disk drive HDD solid state drive SSD ...
Page 184: ...184 Upgrade and Maintenance Manual RX1330 M3 Fans ...
Page 222: ...222 Upgrade and Maintenance Manual RX1330 M3 Expansion cards and backup units ...
Page 244: ...244 Upgrade and Maintenance Manual RX1330 M3 Processor CPU ...
Page 310: ...310 Upgrade and Maintenance Manual RX1330 M3 System board and components ...