![Fujitsu PRIMERGY RX1330 M3 Upgrade And Maintenance Manual Download Page 333](http://html.mh-extra.com/html/fujitsu/primergy-rx1330-m3/primergy-rx1330-m3_upgrade-and-maintenance-manual_121086333.webp)
RX1330 M3
Upgrade and Maintenance Manual
333
Appendix
Indicators on the hot-plug HDD module
Figure 241: Indicators on the hot-plug HDD module
Pos. Label
Indicator
Status
Description
1
Access
indicator
off
The HDD is inactive.
green on
The HDD is being accessed.
2
Error
indicator
off
No HDD error detected.
orange on
An HDD error has been detected.
Possible causes:
– The drive is defective and needs
replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
orange
flashing
slowly
HDD RAID rebuild is in progress.
Data is being restored after
replacing a drive that has been
combined into a RAID array.
!
Summary of Contents for PRIMERGY RX1330 M3
Page 20: ...Upgrade and Maintenance Manual RX1330 M3 Contents ...
Page 48: ...48 Upgrade and Maintenance Manual RX1330 M3 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual RX1330 M3 Basic hardware procedures ...
Page 132: ...132 Upgrade and Maintenance Manual RX1330 M3 Power supply unit PSU ...
Page 178: ...178 Upgrade and Maintenance Manual RX1330 M3 Hard disk drive HDD solid state drive SSD ...
Page 184: ...184 Upgrade and Maintenance Manual RX1330 M3 Fans ...
Page 222: ...222 Upgrade and Maintenance Manual RX1330 M3 Expansion cards and backup units ...
Page 244: ...244 Upgrade and Maintenance Manual RX1330 M3 Processor CPU ...
Page 310: ...310 Upgrade and Maintenance Manual RX1330 M3 System board and components ...