54
Operating Manual
RX1330
M1
Hardware installation
5.3.1
Connecting the monitor
Ê
Plug the data cable for the monitor into the video connector on the server
(item 4 in figure
4 on page 53
).
V
CAUTION
The height of VGA cable connectors can vary. Please make sure that the
VGA connector cables do not interfere with the server below.
Ê
Connect the insulated connector on the monitor power cable to a grounded
outlet in the rack's socket strip (see also the technical manual for the rack).
5.4
Connecting the server to the mains
In its basic configuration the server has a permanently installed power supply
unit or a hot-plug power supply unit. Besides the hot-plug power supply unit, a
second hot-plug power supply unit can be installed optionally to serve as a
redundant power supply. If one power supply unit fails, the second power supply
unit in the redundant configuration ensures operation can continue
uninterrupted.
V
CAUTION!
The server is automatically set to a mains voltage in the range 100 V -
240 V. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Ê
Connect the power cord to the server power supply unit.
Ê
Connect the mains connector to an outlet on the rack's socket strip.
I
For details, please see the technical manual for the rack.
Summary of Contents for PRIMERGY RX1330 M1
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY RX1330 M1 Operating Manual Edition July 2014 ...
Page 6: ...Operating Manual RX1330 M1 ...
Page 10: ...Operating Manual RX1330 M1 Contents ...
Page 14: ...14 Operating Manual RX1330 M1 Introduction ...
Page 76: ...76 Operating Manual RX1330 M1 Starting up and operation ...
Page 78: ...78 Operating Manual RX1330 M1 Property and data protection ...