![Fujitsu Primergy RX100 S3 User Manual Download Page 197](http://html.mh-extra.com/html/fujitsu/primergy-rx100-s3/primergy-rx100-s3_user-manual_121070197.webp)
197
PRIMERGY RX100 S3 User’s Guide
Inst
allin
g I
nte
rn
al O
pti
ons
7
7.6.3 How to Install the Internal Hard Disk Unit
1
Turn off the server and all peripheral devices. Also unplug all power cables from
the server.
"1.4.3 Turning Off the Server" (pg.33)
2
Touch a metal part of the server to discharge static electricity.
3
Remove the dummy unit from the bay where an internal hard disk unit will be
installed.
A dummy unit is installed in a bay where internal hard disk unit is not installed. Pressing the tabs
on both sides of the dummy unit inward, pull it out forward.
Be sure to keep the removed dummy units for later use.
4
Install the internal hard disk unit to the server.
Insert the internal hard disk unit all the way into the bay with the handle lifted.
5
Hold down the handle of the internal hard disk unit until it clicks.
Tabs
Handle
Handle