5.5.3 Notes on Advanced Uninterruptible Power Supply
(UPS)
Note the following points when using an advanced uninterruptible power supply (referred to as UPS
afterward).
■
UPS Shutdown Time Setting
Specify enough time for the UPS power-off time (time from the shutdown direction to the actual power-
off). If this time is set insufficiently, the power will be cut off before system shutdown, which may result
in destruction of data. For more details, refer to the manuals for UPS and UPS management software.
■
Power Supply Control by UPS
Change the BIOS Settings to turn on the server automatically at power recovery or during scheduled
operation using the UPS management software (PowerChute Network Shutdown, PowerChute Business
Edition).
1
Start the BIOS Setup Utility.
"8.1.1 Starting and Exiting the BIOS Setup Utility" (pg.202)
2
Select the [Power On/Off] submenu from the [Advanced] menu, and press the
[Enter] key.
The [Power On/Off]submenu window appears.
3
Set [Power Failure Recovery] to [Always On].
4
Save changes and exit the BIOS Setup Utility.
5.5.4 Turning the Power On via a LAN
You can turn on the server from a client (via a LAN) by utilizing the Wakeup on LAN (WOL) function.
Be sure to install ServerView to control the power supply via a LAN.
When the power cable is disconnected from the server or the server is powered off due to power
interruption, restart the server. Unless the server is restarted, the WOL function will be disabled.
Only the onboard LAN supports the WOL function on this server. To control power supply via a LAN,
make sure you connect the onboard LAN and set the onboard LAN adapter bind to "1".