Error Messages on the Monitor
Problem Solutions and Tips
7.12
Error Messages on the Monitor
The meaning of the error message is contained in the manual for BIOS Setup
and in the documentation for the boards and programmes used.
7.13
Error Messages on the Control Panel
An error message always contains two lines. The first line contains the error
message; the second line contains the date and time in the form
month/day/year hours:minutes
(e.g. 01/28/00 11:39 AM).
The table below shows an outline of possible messages in the LCD panel:
Message
Cause
Reaction
RED_FAN#_FAILED
Fan no. # in the
redundant cooling
system has failed.
Exchange the fan;
redundant fan undertakes
cooling.
FAN#_FAILED
Fan no. # in the non
redundant cooling
system has failed.
Exchange the fan.
V
CAUTION!
Cooling is
guaranteed
completely no more;
possible
overheating of the
system!
FAN#_CRITICAL
Fan no. # does not run
with full power (rotation
speed).
Exchange the fan in a
reasonable amount of time.
WARNING_TEMP#
Adjusted temperature
warning limit (# in °C)
achieved.
Observe the temperature
V
CAUTION!
A further increase of
the temperature
leads to the
automatic shutdown
of the system.
Table 3: Messages on the LCD Panel