U41271-J-Z156-2-76
67
Problem Solutions and Tips
System Fails to Boot
7.9
System Fails to Boot
The system will not boot after installing a new hard disk drive.
SCSI configuration incorrect (Ultra Wide SCSI Controller)
Ê
In the SCSI configuration menu check the settings for the hard disk drives
(SCSI Device Configuration) and the settings under Advanced Configuration
Options.
7.10
Drives “dead” at System Boot
This error message may occur when the server has a RAID controller:
SCSI Cabling Incorrect
Ê
Contact our Service organization.
The RAID Controller Configuration is Incorrect
Ê
Check and correct the settings for the drives with the RAID configuration
utility.
Further information is provided in the manual on the RAID controller.
7.11
Added Drive Defective
This error message may occur when the server has a RAID controller:
RAID Controller is not Configured for this Hard Disk Drive
The drive was probably installed with the system switched OFF.
Ê
Reconfigure the RAID controller for the hard disk drive. Information is
contained in the documentation on the RAID controller.
or
Ê
Reinstall the drive while the system is switched on.
If the hard disk drive continues to be shown as defective, then replace it (see
section “Installing/removing a hard disk drive module” on page 76).