14
Operating Manual
CX420
S1
Functional overview
Electrical data (hot-plug power supply unit)
Ambient conditions
Condensation during operation must be avoided!
Rated voltage range
200 - 240 V / 100 - 240 V
Frequency
50 Hz - 60 Hz
Max. rated current
12 A
Effective power
1200 W
Apparent power
1445 VA
Heat dissipation
4320,0 kJ/h (4080 BTU/H)
Main power fuse
16 A
Protection class
I
Power supply configuration note
2 PSU (High Line / Wide Range);
depends on which PSU option is
used
Power supply efficiency
94% (at 50% PSU load, CSCI
“platinum”)
Electrical value notes
Active power max. value depends on
system configuration.
For details see "Power Configuration
Tool".
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5°C ~ 35°C
Transport (2K2)
-25 °C ~ +60 °C
Humidity
10% ~ 85% (non condensing)