12.2.1.2 Indicators on the front panel (node-related)
Power-on indicator (green)
Does not light up
when the server node is switched OFF.
Lights up green
when the server node is in power-on delay and
while the system is in normal operation (S0).
Flashes slowly (1/2 Hz) green
when the iRMC S5 is initialized and
is getting ready.
Power-off indicator (AC connected)
(green)
located above the On/Off button
Does not light up
in the following cases:
– the server node is not connected to the mains
– the server node is powered on and in normal operation (S0)
Lights up green
in the following cases:
– the server node is in power-off mode but connected to the mains
(AC connected)
– the server node has been switched on and is in power-on delay
I
After connecting the server enclosure to the mains it takes
about 60 seconds until the server nodes enter the standby
mode.
Global error indicator (orange)
–
Lights up orange
if a prefailure event has been detected that
requires (precautionary) service intervention.
–
Flashes orange
if an error was detected that requires service
intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the ServerView Operations Manager or via
the iRMC S5's Web interface.
!