224
Upgrade and Maintenance Manual
CX2550/60/70 M4
Processor (CPU)
Ê
"Shutting down the server node" on page 50
Ê
If applicable, remove all external cables from the server node.
Ê
"Removing the server node from the server enclosure" on page 51
8.3.2
Removing the LC heat sinks
Figure 111: Removing the memory modules covers and VRM heat sink covers
Ê
Remove the memory modules covers (1) and the VRM heat sink covers (2).
Figure 112: Removing the memory modules LC heat sink clamps
Ê
Remove the memory modules heat sink clamps (see circles).