47
PRIMERGY BX600 S3 Blade Server System Unit Hardware Guide
■
How to remove FC Network Blades
1
Touch a metal part of the Chassis to discharge static electricity.
2
Disconnect the Fibre Channel cable connected to the FC Network Blade.
3
Lower the SFP module lever, unlock the lock and remove.
The figure shows an example using FC Pass-
Thru Blade.
4
Remove the FC Network Blade.
The figure shows an example using FC Pass-
Thru Blade.
1. Grip and pull on the handle.
2. Pull the FC Network Blade towards
you and remove it.
5
Install the Network Blade/dummy Switch Blade.
How to install LAN Network Blades" (p.45)
How to install a FC Network Blade" (p.48)
The procedure for removing the dummy Switch Blade is the same as that for removing the LAN
Network Blade. Be sure to keep the removed dummy Switch Blades for later use (
Removing LAN Network Blades" (p.42)).
After removing the FC Network Blades/dummy Switch Blade, do not operate the Chassis with an
empty slot. Be sure to install a Network Blade or a dummy Switch Blade.
SFP module
Lever
(1)
(2)
Handle
Summary of Contents for PRIMERGY BX600 S3