22
Chapter 3 Standard Operations
3.2 Turning On the Server
1
Open the rack door.
"3.1 Opening the Rack Door" (p.20)
2
Power on the display and peripheral devices.
3
Press the main power switch on the front of the Chassis.
Press the switch until the main power supply
LED of the Chassis turns green.
When turning on the chassis' main power, the system fan unit and Network Blade start. It
takes about one minute for the Switch Blade to become fully operational.
When turning on the chassis' main power, the Server Blade operation varies depending
on the settings of "After Power Failure" in the BIOS settings.
・
For [Stay Off], the Server Blade does not start until its power is turned on.
・
For [Last State], the Server Blade is in the same status as when the chassis' power is
turned off.
・
For [Power On], the Server Blade's power is turned on and the Server Blade starts.
• Do not move, strike, or shake the server when it is turned on. Doing so may damage the hard
disk and cause data to be lost.
• Turn the server on when the temperature is in its operating environment range (10 – 35
°
C). For
details about the operating environment, refer to "Start Guide" and "Safety Precautions".
When operating the device outside of this operating environment, the server may operate
improperly, damage data etc.
When operating the device outside of this operating environment, Fujitsu cannot be held
responsible for any related damage, malfunction, or loss of data, etc.
• The fans rotate at high speed immediately after the power of the Chassis is turned on, but this
is not defective. When the temperature is within the server's operating environment range (10
– 35
°
C), they will start to rotate at normal speed later.
• Do not turn on the main power supply of the Chassis until at least 2 minutes has passed since
the power supply cable was plugged in.
• Be sure to wait for 10 seconds or longer after shutdown of the main power supply of the
Chassis or the Server Blade before turning the server on.
Main power LED
turns green
Main power switch