5.3 Notes on System Design
Table 5.15 Addition of a VLAN Tag to BPDU
5.3.3
Port mirroring
Mirroring of CPU-sent frame
• Symptom
In a certain configuration, a frame sent from the CPU cannot be mirrored.
• Cause
Frames sent from the CPU cannot be copied across chips.
Table 5.16 CPU-send frame mirroring enabled/disabled
STP
BPDU
filter
Source BPDU
Output port
VLAN setting
Output BPDU
Enable
-
-
Port VLAN
Without a VLAN Tag
Tag-VLAN
Disable OFF
Without a VLAN
Tag
Port VLAN
Without a VLAN Tag
With a VLAN Tag
Port VLAN
With a VLAN Tag
The Tag is the same as that of the
source BPDU.
ON
-
-
-
Mirror port
(destination)
Monitored port (source)
IOU 0 0 - 3 1
GigabitEthenet0/3-0/4
GigabitEthenet 0/7-0/8
IOU 4 0-7 1
GigabitEthenet 0/1-0/2
GigabitEthenet 0/5-0/6
TenGigabitEth
enet 1/1
TenGigabitEth
enet 1/2
IOU 0 0-3 1
GigabitEthenet 0/3-0/4
GigabitEthenet 0/7-0/8
Enabled
Disabled
Disabled
Disabled
IOU 4 0-7 1
GigabitEthenet 0/1-0/2
GigabitEthenet 0/5-0/6
-
Enabled
Disabled
Disabled
TenGigabitEthenet 1/1
Disabled
Disabled
-
Disabled
TenGigabitEthenet 1/2
Disabled
Disabled
Disabled
-
Summary of Contents for PRIMEQUEST 440
Page 1: ...C122 B001 02EN Front Cover SYSTEM DESIGN GUIDE ...
Page 2: ......
Page 6: ......
Page 8: ......
Page 14: ......
Page 16: ...viii C122 B001 02EN NOTE ON SAFETY Rear view Unit rear ...
Page 18: ...x C122 B001 02EN NOTE ON SAFETY PCI_Box Left side view Front view without cover ...
Page 20: ......
Page 106: ......
Page 127: ...C122 B001 02EN 4 21 4 2 MMB Functions Figure 4 15 Console Redirection Switch screen ...
Page 178: ...5 34 C122 B001 02EN CHAPTER 5 Business LAN Management by GSWB ...
Page 208: ......
Page 218: ......
Page 234: ......
Page 248: ......
Page 264: ......
Page 276: ......
Page 279: ......
Page 280: ...Back Cover ...