5.1 Security Settings
SNMP v3 setting
This function sets an SNMP v3 specific engine ID and user.
Notes:
If the engine ID or IP address is changed, the user set for SNMP v3 access
must be completely set again from the beginning. To validate the set user,
temporarily stop the SNMP daemon and then restart it. Therefore, if the
[Apply] button is clicked here, the SNMP service is temporarily stopped.
• Procedure
1
Click [Network Configuration]
→
[SNMP Configuration]
→
[SNMP v3
Configuration].
The [SNMP v3 Configuration] window is displayed.
Figure 5.6 [SNMP v3 Configuration] window (example)