4-120
C122-E001-10EN
CHAPTER 4 Work Required After Operating System Installation
4.9.3.4
Setting the kdump service
Enter the following so that the kdump service automatically starts when the system
boots.
Enter the following to check whether the dump service has been set correctly.
The settings are displayed as shown below:
4.9.3.5
Setting the kernel parameter
Specify the following with the kernel parameter append in /boot/efi/efi/redhat/
elilo.conf.
4.9.3.6
Rebooting the system
Enter the following to reboot the system.
# chkconfig kdump on
# chkconfig -- list kdump
kdump 0:off 1:off 2:on 3:on 4:on 5:on 6:off
append="
· · ·
crashkernel=512M@256M"
# reboot