4-90
C122-E001-10EN
CHAPTER 4 Work Required After Operating System Installation
Verifying the trap transfer destination setting
To verify the trap transfer destination setting, use the standard SNMP Service trap that
is normally used during the SNMP Service restart in step 10. Check the reception of
this trap to verify the transfer destination setting.
Remarks:A trap receipt application or trap manager must be active at the trap transfer
destination to ensure that standard SNMP Service traps can be received.
On the trap transfer source machine, restart SNMP Service by performing step 10.
As a result, the trap receipt application at the trap transfer destination receives the
"ColdStart" standard SNMP Service trap.
For example, if the trap transfer destination is a Linux machine, the following
message is added to syslog when snmptrapd receives the trap, and this indicates that
the trap transfer destination can correctly receive such traps.
Aug 17 14:50:03 shaka snmptrapd[2600]: 2005-08-17 14:50:03
pq-server.fujitsu.com [192.168.0.162] (via 192.168.0.162) TRAP, SNMP
v1, community public SNMPv2-SMI::enterprises.211.1.31.1.2.100.3 Cold Start Trap
(0) Uptime: 0:00:00.00
4.6.3
Setting the destinations of trap and e-mail sending via the MMB
Note:
z
Perform the tasks for this setting only if the setting is required.
z
The setting is required for linkage with operation management software.
Destinations for trap and e-mail sending via the MMB are the addresses set with the
MMB Web UI.
See
Section 5.1.2, "System SNMP setting."
for the MMB trap destination. See
Section 2.2.3.5, "SMTP settings."
for the e-mail destination.
4.6.4
Windows firewall setting
To run your system with the Windows firewall enabled, specify [Exceptions] for the
following ports to guarantee that data can be sent to and received from the MMB
through the following ports:
z
TCP port used by PSA: 24450 port
z
TCP port used for SNMP: 161 port
Summary of Contents for PRIMEQUEST 400 Series
Page 1: ...C122 E001 10EN Front Cover INSTALLATION MANUAL ...
Page 2: ......
Page 18: ...x C122 E001 10EN NOTE ON SAFETY Extended Power Cabinet ...
Page 19: ...C122 E001 10EN xi NOTE ON SAFETY Extended I O Cabinet ...
Page 20: ...xii C122 E001 10EN NOTE ON SAFETY PCI_Box ...
Page 21: ...C122 E001 10EN xiii NOTE ON SAFETY PRIMEQUEST 520A 520 420 Main unit ...
Page 22: ......
Page 24: ......
Page 42: ......
Page 46: ......
Page 122: ......
Page 186: ......
Page 354: ......
Page 356: ......
Page 394: ......
Page 428: ......
Page 445: ......
Page 446: ...Back Cover ...